Souvenir & AksesorisLibreVNA 100kHz – 6GHz USB Based Full 2-port 2CH Vector Network Analyzer CNC Housing
Availability:
$ 93.03
SPECIFICATIONS:
| MODEL |
MARUTI – 1234 – DESCRIPTION CE – ISO 9001 CERTIFIED 100% OIL FREE COMPRESSOR, OIL LESS, NON-LUBRICATED MEDICAL GRADE AIR COMPRESSOR, FOR PHARMACEUTICALS, FOOD, MEDICAL AND SURGICAL HOSPITALS, ANALYTICAL, R&D LABORATORIES ETC. APPLICATIONS. |
| Motor HP |
2 Three Phase MARUTI MAKE |
| KW |
1.49 |
| NO.OF POSITION |
2 |
| PISTON DISPLACEMENT IN CFM |
9.4 |
| Ltr/Min |
266 |
| m3/hrs |
16 |
| m3/min |
0.26 |
| PRESSURE PSIG |
10.0 BAR/145 PSI |
| AIR TANK CAPACITY IN LITERS |
160 LTR. Size 16” x 50” inch 4mm shall / 5mm disk. |
| HZ |
50 |
| NET WEIGHT |
Length 57″ Width 30″ Height 38″ In inches and Weight without packing 155KG APPROX |
| GROSS WEIGHT |
Length 59″ Width 32″ Height 40″ In inches and Weight with packing 175KG APPROX |
| WARRANTY |
12 MONTHS WARRANTY AGAINST MANUFACTURING DEFECT |
LibreVNA 100kHz – 6GHz USB Based Full 2-port 2CH Vector Network Analyzer CNC Housing LibreVNA (TM) is a USB based full 2-port vector network analyzer designed by Jankae. Using 3 ADCs to sample data simultaneously and using FPGAs for signal processing, it is capable of scanning over 10,000 points of full dual-port measurements in less than 1 second. The ultra-low noise power supply design and the use of 16bit ADC, together with the precision CNC’s aluminum shielded housing, achieve up to 100dB of effective dynamics. Many aspects are already comparable to lab-grade VNAs, but this is still a work-in-progress project. Some design features may not be perfect, especially the performance will drop when the frequency is higher than 3GHz, please fully understand the possible limitations before buying this machine. If you have any suggestions for future releases, please feel free to contact us as well. Specifications Impedance 50Ω Test Port Connector SMA, female Number of Test Port 2 Frequency Range 100kHz to 6GHz Frequency Accuracy <2ppm Number of Measurement Points 2 to 4501 Speed 2-port – 4000 pts <500ms (IFBW=50 kHz ) Measurement Bandwidths 10Hz to 50kHz Dynamic range (IFBW 10Hz) > 95 dB to 3GHz > 50 dB to 6 GHz (Note 1) Measurement parameters S11, S21, S12, S22 Reflection directivity > 40 dB (after calibration) (Note 2) Output power -40 dBm to 0 dBm (Note 3) Power Supply DC 5V, 1.5A(USB powered, or 3.5mm connector) Power consumption approx. 7W. Interface USB type-C Supported Operating System Windows, Linux, MacOS. (Only 64-bit software is available for now) External Reference Input SMA female; 10 MHz; External Reference Output SMA female; 10 MHz or 100MHz; Further measurement options Simple spectrum analyzer (Lack of mirror suppression and slower speed) Signal generator (Not precisely calibrated) Note 1:Due to structural limitations, S12 isolation is 10dB worse than S21. Above 3GHz, the performance decreases with increasing frequency, and the port isolation is only 50dB at 6GHz. Below 1MHz, the performance decreases with decreasing frequency, and the effective dynamic decreases to 70dB at 100kHz. Note 2:The use of higher accuracy calibrators allows for higher precision measurements. Note 3:The output power may decrease when the frequency is lower than 1MHz or higher than 3GHz. LibreVNAis a trademark that we have registered or are in the process of registering in several countries. If you are building a VNA based on an open source project, please avoid using this trademark.
Looking Dealer
2hp Oil Free Oil Less Medical Air Compressor Pump Manufacturers and Exporters Suppliers Dealer Traders In UP Bihar Maharashtra West Bengal MP Rajasthan Tamil Nadu Karnataka Gujarat AP Odisha Telangana Jharkhand Kerala Assam Punjab Chhattisgarh Haryana Delhi JK Uttarakhand Himachal Pradesh Tripura Meghalaya Manipur Nagaland Goa Arunachal Pradesh Puducherry Mizoram Chandigarh Sikkim